一、產品概述
HAO07-4X-10/16Q型氣、液動(dong)角(jiao)式排(pai)(pai)(pai)污(泥)閥采用(yong)活塞式雙室(shi)驅動(dong),工作靈敏(min),開啟高度大于DN2,排(pai)(pai)(pai)污暢(chang)通無(wu)阻,排(pai)(pai)(pai)污后能自動(dong)沖洗(xi)等特點(dian),主(zhu)要用(yong)來排(pai)(pai)(pai)除各種水(shui)池和(he)容(rong)器(qi)的(de)沉(chen)淀(dian)污物(wu)。廣泛應用(yong)于各類水(shui)廠(chang)沉(chen)淀(dian)水(shui)池及(ji)工礦企業的(de)排(pai)(pai)(pai)污之用(yong)。
二、技術參數
三、工作原理
由(you)電磁(ci)閥通過控(kong)制(zhi)管(guan)路(lu)對雙控(kong)制(zhi)室的(de)活塞實現控(kong)制(zhi),夕卜(bu)供(gong)給電磁(ci)閥的(de)驅(qu)動源采用壓(ya)縮空氣或壓(ya)力(li)(li)清水,驅(qu)動的(de)工作(zuo)壓(ya)力(li)(li)P 可取:0.2MPaw Pw 1 .OMPa
控制原理的原則概述如下:
當電(dian)磁(ci)閥斷(duan)電(dian)時(shi),排泥(ni)閥應處(chu)于關閉(bi)狀(zhuang)態(tai),此時(shi)排污閥活(huo)塞上控制(zhi)室(shi)(shi)應與(yu)壓力(li)驅動(dong)源相(xiang)(xiang)通(tong)(tong)(tong)與(yu)大氣隔斷(duan),而下控制(zhi)室(shi)(shi)與(yu)大氣 相(xiang)(xiang)通(tong)(tong)(tong);當電(dian)磁(ci)閥通(tong)(tong)(tong)電(dian)時(shi),排泥(ni)閥應處(chu)于開啟狀(zhuang)態(tai),此時(shi)排污閥活(huo)塞下控制(zhi)室(shi)(shi)應與(yu)壓力(li)驅動(dong)源相(xiang)(xiang)通(tong)(tong)(tong)而與(yu)大氣隔斷(duan),上控制(zhi)室(shi)(shi)則與(yu)大 氣相(xiang)(xiang)通(tong)(tong)(tong)。
一個兩位五通的電磁閥可(ke)(ke)以控(kong)制成組個排泥閥工(gong)作,用壓縮空氣作驅使動源,可(ke)(ke)同(tong)時控(kong)制更多個排泥閥。
四、 安裝與調試
安裝可參閱圖,閥(fa)體不應承受(shou)管理網的(de)重量(liang),宜在排污閥(fa)的(de)進口處安裝一個同規格的(de)閘(zha)閥(fa)以便(bian)于維修(xiu)。
安裝后應(ying)進(jin)行調(diao)試(shi),調(diao)試(shi)時(shi)要仔(zi)細(xi)檢查所有管路安裝是否合理,有沒在泄漏等問題。運行試(shi)驗(yan)時(shi)主要檢查電磁閥斷電時(shi)排泥 閥應(ying)處于(yu)全關閉狀(zhuang)(zhuang)態,無泄漏;通電時(shi)應(ying)處于(yu)全開啟(qi)狀(zhuang)(zhuang)態。
五、 維修和保養
只要避免人為的(de)損壞和凍傷,無(wu)需頻繁的(de)維修。若(ruo)要拆卸(xie)維修,只需松開缸體(ti)與閥體(ti)的(de)緊(jin)固螺栓,利(li)用設計在(zai)缸法(fa)蘭上的(de) 兩個(ge)啟頂螺孔,將缸體(ti)和閥體(ti)頂開,即可(ke)卸(xie)下所有零部件(jian),進行(xing)維修操作(zuo)。
平時要定期對活(huo)塞潤滑進行檢(jian)查,活(huo)塞磨擦面應有少(shao)量(liang)無垢潤滑油為佳。